Boilermate 2000 installation manual

We have a boilermate 2000 with a baxi solo ii pf50, which is now slightly underpowered following a couple of house extensions. Amtrol boilermate indirect water heaters indirect water. A conventional central heating boiler heats the water in the boilermate 2000 directly. Gledhill boilermate aclass sp anyone have experience of. Boilermate, electramate, pulsacoil manuals to help fix. The heat link is just connected to the live, neutral and switched live thermostat terminals on the boilermate, wired as per the switched live diagrams in the nest manual. It is also suitable for upgrading existing traditional hot water. The boiler works fine and just had maintenance done. Gledhill boilermate 2000 design, installation and servicing.

The boilermate instructions show a typical installation using the tp5000 units. Replacing and alternatives to a gledhill boilermate. Instructions issued by the manufacturers of the heat source e. The lady had tried to put the electrical boost function on the cylinder but was still not getting any hot water. The boilermate aclass is only suitable for use with an open vented central heating system. I specialise in repairing gledhill thermal stores including all versions of the gledhill boilermate. Gledhill boilermate 2000 thermal store advice please. Boilermate 2000 gledhill gt155 circuit board operation.

The boilermate ii or 2 is the same as the boilermate original from a plumbing point of view, so if you notice this list seems to be the same as the list for the boilermate original, youre right, it is, but ive added some photographs to this section. Boilermate 2000 pcb problem screwfix community forum. This requires the potterton boiler in the utility room to be relocated to allow ventilation. The boilermate 2000 is designed to provide improved space heating and mains pressure. Mar 02, 20 hoping for a bit of advise, i moved into a then new build wimpey home 8 years ago which has a boilermate 2000 to control the heatinghot water. Boilermate 2000 with potterton suprima boiler mybuilder. Jul 16, 2012 we have a boilermate 2000 with a baxi solo ii pf50, which is now slightly underpowered following a couple of house extensions. With three decades of proven performance and reliability, the classic series remains the industry standard. Boilermate 2000, hot water is run off the main cold water via a coil inside tank. The boilermate 2000 is designed to provide improved space heating and mains pressure hot water when coupled to any remotely sited condensing or none condensing. Will the nest thermostat work with a gledhill boilermate 2000. Jun 28, 2008 hello there, my boilermate 2000 is 10 years old and has started to leak badly.

Separate instructions for this will have been left for you by the installation. At dhs we offer a range of spare parts for the gledhill boilermate 2000 185. The boilermate deaerator removes oxygen economically and with trouble free performance. This video shows how a gt155 pcb fitted to a boilermate 2000 unit works. The champion series boilermate is the latest addition to amtrols extensive. The product known as boilermate has been around for a long time. Gledhill pulsacoil 2000, things to check if no hot water. In the interest of continuously improving the boilermate cp range, gledhill building. More efficient than conventional gas or electric water heaters, boilermate indirects provide more hot water, use less energy and require no venting or additional utility connections. The hw pump has been temporarily wired to the power input terminals on the pcb with an inline switch to allow isolation when not in use as only required while showering. Built of corrosionresistant alloys for lifetime service, the deaerator employs those basic principles of gas removal proven most effective and economical. Working in guiseley leeds taking out a boilermate 2000 and glow worm micron replacing ideal vogue, boiler replacement combi boilers replaced. The stored water is pumped to the boiler for heating and back again by the lefthand of the three pumps behind the front panel of the unit whenever the stored water temperature drops below a specific temperature set in the factory.

The pcb has mains electricity on it so extreme caution should be used. The boilermate 2000 is not covered by section g3 of the current building regulations and is therefore not notifiable to building control. All goods are sold subject to our conditions of sale, which are set out at the rear of this manual. We have installation and service manuals for the following makes of boiler and these are all free. He then found the main circuit board in the boiler glowormhad also blown.

Working in guiseley leeds taking out a boilermate 2000 and. After phoning several tradesmen, the suggestion is to remove both and have a combi fitted either valliant or ideal logic. Reply to gledhill boilermate 2000 and honeywell evohome in the central heating forum area at. Boilermate thermal storage system by gledhill gledhill response. Apr 03, 2019 boilermate 2000 gledhill gt155 circuit board operation duration. At the moment i dont have an airing cupboard, just a cupboard full of the boilermate it its associated plumbing.

I have a wh7p boilermate and the thermostat is turned up to 7 and the water is only warm. The boilermate 2000 is only suitable for use with an open vented central heating system. I provide no warranty with these instructions and any result of you making these. I was a bit wary but my learnings on this so far are water is by design very hot, useful for instant heating in winter but perhaps too hot. Boilermate for sale in uk 54 secondhand boilermates. The airing cupboard is so hot that the bedrooms are very hot this time of year, it must be using far too much gas. Gledhill boilermate 2000, what can i replace it with. Boilermate 2000 the boilermate 2000 shown schematically above is designed to provide improved space heating and mains pressure hot water when coupled to any remotely sited condensing or non condensing boiler. Boilermate 2000 service manual only afterwards lesson the paper boilermate 2000 service manual 1825469c you acquire no else interviews afflicts you previously that phase. A report by the cranfield institute of technology found that this system gives a potential for energy savings of up to 15%. Changing boilermate 2000 to a combi boiler mybuilder. For those unfamiliar, the boilermate was installed in a lot of modern homes in the 2000s. I have a wh7p boilermate and the thermostat is turned up.

On board diagnostics that can be interrogated remotely and fault tolerant electronics give robust performance. What to look for if you get central heating, but no hot water. I have a boilermate wh7l water heater that recently the smart panel on the front is making a clicking noise along with the switch on the boiler. Boilermate 2000 userguide switch gas council approved reference. I also have a potterton suprima boiler in the kitchen both are on the ground floor. Boilermate bp the boilermate bp is an open vented thermal store that does not require expensive safety valves and it provides mains pressure hot water. The boilermate aclass is not covered by section g3 of the current building regulations and is therefore not noti.

Have no instructions for he boilermate although i did find a manual online and am totally baffled by the whole system. It has however evolved during this time and if you are replacing an elderly unit or for that matter planning to incorporate one in a new installation you should be aware if fundamental differences between old and new models. Boilermate 2000 new boiler screwfix community forum. Boilermate deaerator operation and maintenance manual. I have a boilermate wh7l water heater that recently the. True to their heritage, boilermate hot water makers offer great value and dependable performance with options to fit any installation and budget. Amtrol invented the indirectfired water heater over 30 years ago, redefining the best solution for fast, efficient and reliable hot water.

Amtrol invented the first indirectfired water heater, using the existing energy in a boiler system to minimize fuel use and maximize hot water output. Separate instructions for this will have been left for you by the installation engineer, or you can refer to the instructions on the label on the front of the appliance. Hi, i have a boiler mate set up in my home, im wondering what type of thermostat i need to buy to control the heating. The heating works on individual thermostatically controlled radiators. I looked inside the cover of the boilermate 2000 cylinder and could see that the display on the pcb was blank, although two of the green leds were lit and two of the. Boilermate 2000 gledhill gt155 circuit board operation youtube. The pulsacoil 2000 was a major improvement over the preceding model the pulsacoil iii. Gledhill boilermate a class design, installation and.

The principle was developed in conjunction with british gas. If you call me for a repair to your boilermate it will always be me who turns up, not an employee or subcontractor who may or may not be fully familiar with your. Looking at the manual for the boilemate 2000, it would connect to terminals 9, 10 and 11. The whole appliance was built inside a rectangular metal case with all the control components concealed inside, rather than being attached to the outside and vulnerable to physical damage as with the preceding pulsacoil iii. Genuine gledhill boilermate 2000 fully working pcb this was replaced around 5 years ago and taken from a working boilermate that was replaced due to heating upgrade. Looking at the manual for the boilemate 2000, it would connect to terminals 9, 10 and 11, remembering to remove the link between 9 and 11. The problem is the dhw is far too hot making it difficult to get a good shower temperature. It seems like its not staying on long enough for the boiler to start up. Manuals gledhill parts gledhill boilermate gledhill.

The information in this manual is provided to assist generally in the selection of equipment. Mar 23, 2016 working in guiseley leeds taking out a boilermate 2000 and glow worm micron replacing ideal vogue, boiler replacement combi boilers replaced. Water heater gledhill pulsacoil stainless installation instructions manual 36 pages. I have a baxi back boiler and a large boilermate 2000. According to the property history, none of the hot waterheating system has ever been serviced the house is 7 years. As with all boilermates, the boilermate aclass is to separate the heat generator e. It has a brand new worcester boiler not a combi and a boilermate 2000. The classic series is the indirect water heater that started it all. Hoping for a bit of advise, i moved into a then new build wimpey home 8 years ago which has a boilermate 2000 to control the heatinghot water. Gledhill spare parts is an essential business and remains open for trade.

If its installation instructions, or user manuals you are looking for, visit our. Boilermate, electramate, pulsacoil manuals to help fix problems. Boilermate 2000 about the gledhill boilermate manualzz. Below is a list of relevant documents in suitable categories which can be viewed online. Model flx installation instructions 750154 0806 flexible watertube boiler hot water. Boilermate 2000 with potterton suprima boiler hi, we are extending our house 2 storey extension from a 4 bed to a 6 bed. Boilermate bp manual discontinued stainlesslite plus heat pump manual. The boilermate 2000 is not covered by section g3 of the current building regulations and is therefore not noti. If youre an installer looking for technical advice regarding a gledhill unit you are.

Below is a direct link to brochures, installation and operating instructions and submittal data sheets for each product. Im seriously considering having the systems boiler and boilermate replaced in the summer when its a bit warmer. Oct 26, 2012 i visited to find a glowworm ultimate and boilermate 2000 cylinder. Gledhill boilermate 2000 thermal store advice please page. The boilermate bp is suitable for use with a gas or an oil boiler and the heating system can be either open vented or sealed. Page 1 boilermate 2000 userguide unswitched gas council approved reference numbers boilermate 125 8931704a an open vented central heating boilermate 145 8931705a and mains pressure hot water supply boilermate 185 8931706a system incorporating boilermate 210 8931707a a thermal store boilermate 225 8931708a. We are pleased to provide a full list of user and installation manuals for all gledhill products covered by gledhill response. The cleaverbrooks designed spraymaster deaerator assures high purity effluent by removing oxygen and other dissolved gases in boiler feed. From experience, large industrial plants and utilities have learned that the most practical and economical way to remove oxygen from feedwater is through mechanical deaeration. With all its system components concealed behind a beautifully engineered outer case, it consigns cupboard pipework to the history books and turns installation time into minutes. Water heater gledhill electramate 2000 installation and servicing instructions 44 pages. The gledhill boilermate range is a wbs listed product and complies with the wma speci. These instructions should be read in conjunction with the installation and servicing. The boiler itself works fine an ive replaced anything thats failed over the last 5 yrs or so heat exchanger, fan, pcb, thermostat and im in not great rush to replace it due to efficiency reasons as our heating demands are low bills average.

It started having a problem after a couple of years with the hot water running hotcoldhot intermittently, a common problem with them. Boilermate a is slightly smaller than the boilermate 2000 with the empty weight ranging from 45kg to 56kg vs the 58kg and 88kg of the boilermate 2000. As the product continued to develop boilermate 2000 and later the unit saw the. Think i have most go my head around it but am having difficultly with the timer. Gledhill boilermate 2000 user manual pdf download manualslib. The pcb has mains electricity on it so extreme caution should be. You can find the installation manual for the boilermate 2000 here.

755 67 1433 408 1010 1524 1417 1297 673 1138 1436 1217 1253 505 824 758 524 144 1223 1102 129 612 1211 183 1511 688 1167 613 269 954 981 1062 129 231 1148 953 1135 211